question
what is not identified in the manual as a concern with field coupled hoses
answer
length of hose
question
on effect of some refrigerant gases in the atmosphere is that they
answer
contribute to trapping heat
question
when should recycling equipment filters be changed
answer
according to equipment manufactures specifications
question
select the statement that best describes the chemical and operating characteristics of HFO1234yf
answer
HFO1234yf is similar to, but not the same as,HFC134a
question
why must recycled refrigerant be checked for air
answer
to avoid performance loss, system damage
question
it is not recommended by the US EPA, but adding refrigerant to a leaking system is
answer
permitted, unless local or state laws prohibit it
question
which of the following is unlikely to affect refrigerant charge accuracy
answer
the A/C compressor
question
is it acceptable and legal to vent HFC-134a
answer
no
question
which of the following is not a factor in how much refrigerant can be recovered from an A/C system
answer
the age of the vehicle
question
which type of tank must be used during the transfer of refrigerant
answer
tanks marked DOT 4BA
question
when using an hfc134a refrigerant recovery machine after completing the first recovery process how long must you wait, then check the machines gauges for a rise in pressure above vacuum which would indicate that the system still contains some refrigerant
answer
5 minutes
question
what can happen if refrigerant storage tank is overfilled
answer
tank may explode
question
which air conditioning components must be approved or certified for use in an HFO1234yf system
answer
evaporators
question
paid technicians who service or repair mobile A/C systems using HCFC-22 as refrigerant or service cargo refrigerant equipment
answer
must be section 608 type ii certified
question
what was a key design change for HFC-134a A/C systems versus CFC-12 A/C systems
answer
increased condenser capacity and airflow
question
mobile A/C system design changes new service procedures and equipment have been developed for what reason
answer
to reduce lifetime refrigerant emissions
question
HFC-134a has a global warming potential of
answer
1430
question
the transportation industry is moving to new refrigerants that have lower
answer
global warming potential
question
if a large amount of lubricant is removed from a system during refrigerant recovery
answer
the system likely contained too much lubricant
question
proper way to recharge system
answer
remove charge,evacuate system, add correct amount of refrigerant
question
CFC-12 recovery equipment has SAE 3/8 inch service fittings. HFC-134a recovery equipment has
answer
quick couple design
question
when can HFC134a become combustable in a mobile air conditing system
answer
if shop air is used in the system in an attempt to check for leaks and HFC134a is present
question
when it has been determined that an A/C system has a low refrigerant charge, what should be done
answer
perform a leak detection procedure
question
what is the advantage of using refrigerant identification equipment
answer
allows the ability to determine what type of refrigerant is in system
question
which of the following statements is correct about flushing A/C systems
answer
flushing solvents may remain in A/C systems causing problems