Fireguard Practice: F-02

10 September 2022
4.7 (114 reviews)
52 test answers

Unlock all answers in this set

Unlock answers (48)
question
Fireguards are not required at ___
answer
libraries
question
All fire alarm boxes must be painted ___
answer
red
question
The minimum number of fire alarm boxes required on each floor of a building is ___
answer
1
question
In large buildings, alarm boxes may not be more than ___ feet from eachother
answer
200
question
Alarm boxes must be mounted ___ feet above the floor
answer
3.5-5
question
In an emergency, a fireguards most effective quality is their ___
answer
composure
question
In a fire emergency the fire department may be notified by
answer
Telephone, Radio, and exterior alarm box
question
An exit aisle at least ___ feet wide is required at all locations
answer
3
question
Areas that must not be obstructed include ___
answer
hallways, Stairways, Exits non emergency windows CAN be obstructed
question
Buildings must be checked ___ for potential fire hazards
answer
daily
question
Fire Alarm boxes must be checked___
answer
Daily
question
Sprinkler heads are activated ___
answer
by heat
question
Sprinkle heads that have been activated must be ___
answer
replaced
question
The charge of a fire extinguisher can be checked by___
answer
reading the gauge (in the green is good)
question
Most sprinkler and standpipe systems must be inspected ___
answer
Yearly
question
The Fire Safety plan must be appoved by the ___
answer
Department
question
Fire Guards on office building duty must patrol the entire building at least ___
answer
Once every hour
question
Areas where accumulated garbage present a particular fire hazard are in
answer
Private Offices
question
During their rounds, the fireguard must ___ inspect all fire protection devices
answer
Visually
question
Fireguards are responsible for knowing ___
answer
• Fire protection techniques • Fire safety regulations • Basic firefighting regulations
question
Interior fire alarm boxes are located ___
answer
near exits from floors
question
The two types of fire alarm boxes are ___
answer
• Single action • Double action
question
Once activated, the fire alarm system can only be shut off at the ___ by using a special key
answer
main control panel
question
In a fire emergency, building occupants must be ___
answer
• Instructed to remain calm • Instructed to not use elevators • Evacuated in an orderly fashion
question
In a fire emergency, occupants ___ are NOT immediately seriously threatened by the spread of fire
answer
on the floor below the fire
question
Safety signs likely to be found around a building DON'T describe ___
answer
The type of building construction and fire prevention protection
question
Exit signs posted above doorways must be ___
answer
illuminated
question
The fireguard must wait at the exterior alarm box used in an emergency in order to ___
answer
organize occupants leaving
question
Locks, bolts and chains may be installed on exits when ___
answer
a building is unoccupied
question
Any leaks or breaks in the piping, tanks, valves, etc. of a sprinkler system must be ___
answer
reported to the local fire department company immediately
question
The symbol on a fire extinguisher (A, AB, ABC, or K) indicate the ___
answer
type of fire the extinguisher may be used on
question
A set of ___ extra sprinkler heads must always be kept on the premises if there is a sprinkler system
answer
6
question
In a standpipe system, water is sprayed onto a fire through ___
answer
a hose or nozzle
question
Portable fire extinguishers must be inspected ___
answer
monthly
question
A tag on a fire extinguishers marks ___
answer
the dates and inspector(s) of a the extinguisher month by month
question
Fire extinguishers are generally inspected by ___
answer
a representative of the company holding the maintenance contract for the fire extinguisher
question
An OS&Y valve controls ___
answer
the main supply of water in a sprinkler or standpipe system
question
The OS&Y (Outside Stem and Yoke) valve should be sealed in ___ position:
answer
open
question
An OS&Y is generally sealed with a ___
answer
padlock and chain
question
An OS&Y valve with (a) ___ must be inspected monthly
answer
• Electronic supervision • Padlock and chain
question
An OS&Y valve with a ___ must be inspected weekly
answer
valve lock-seal
question
If one can completely turn the wheel of a OS&Y valve pass the fully opened or closed position, the valve is deemed ___
answer
defective
question
When a part of the sprinkler system or standpipe system is shut down for repairs, the fireguard must ___
answer
notify the fire department (this allows them to adjust the firefighting strategies)
question
General safeguards against fire hazards DON'T include ___
answer
preventing smoking in public buildings
question
If the alarm or sprinkler system of a building is out of service, a fireguard must be on duty ___
answer
24 hours a day
question
Fire wardens and deputy fire wardens are generally ___
answer
trained volunteers provided by building tenants
question
Class A fires
answer
¤ Ordinary combustibles (wood, paper, etc) ¤ Can be extinguished with water, and dry chemicals ¤ Extinguisher symbol: Green Triangle
question
Class Bâ–¡ fires
answer
¤ Flammable liquids and gas (gasoline, motor oil, etc) ¤ Deprive fire of oxygen, inhibit release of combustible vapors ¤ Extinguisher symbol: Red square
question
Class C fires
answer
¤ Electrical fires (live wires, etc) ¤ Requires nonconductive extinguishing agents. Once electrical equipment is deenergized, one can use ABC and BC extinguishers. THERE is no such thing as a C only extinguisher ¤ Extinguisher symbol: Blue circle
question
Class D fires
answer
¤ Combustible metals (magnesium, titanium, etc) ¤ Requires extinguishing agent that does not react with the burning metal. ¤ Extinguisher symbol: Yellow five point star
question
Class K fires
answer
¤ Kitchen/cooking fires (cooking oils, fats, etc) ¤ Relies on saponification to work (alkaline mixture) ¤ Symbol: N/A
question
P.A.S.S
answer
Acronym to remember how to use a fire extinguisher Pull the pin Aim at the base of the fire Squeeze the extinguisher trigger Sweep side to side